Repair of gas water heaters at home: what you can and cannot do yourself
There are gas water heaters in almost every home and are now becoming very popular in city apartments. Modern developers offer fully self-contained housing, independent of interruptions in the supply of heat and hot water. The column takes up very little space, and you are guaranteed to have hot water at any time of the year and around the clock. But what if she suddenly went nuts? The topic of this material by the homemaster.techinfolux.com/en/ editorial office is the repair of gas water heaters at home. We will consider which breakdowns can be corrected with our own hands, and in which cases the gas service master should be called.
The content of the article
- 1 Gas column device and principle of operation
- 2 How to properly turn on the gas column and adjust the temperature and pressure
- 3 How easy it is to check the thrust in the gas column
- 4 What tools are needed to repair a gas water heater with your own hands
- 5 What to do with common gas water heater malfunctions
- 5.1 Repair of the gas column heat exchanger in case of cracks or scale formation
- 5.2 What to do if the gas water heater does not light up
- 5.3 If the gas column igniter goes out after releasing the button
- 5.4 Why does the geyser spontaneously go out, and how to fix the problem
- 5.5 Why does the gas water heater not heat the water
- 5.6 The reason for the weak pressure of hot water from the gas column
- 5.7 What to do if the gas column radiator is leaking
- 5.8 Replacing the gas column gaskets
- 5.9 Video: Neva gas column (Neva) 4510-4511 does not ignite: repair, membrane replacement
- 5.10 What to do if pops are heard when turning on the gas water heater
- 5.11 You smell gas during operation
- 6 Features of repair of popular brands of gas water heaters
Gas column device and principle of operation
Columns for heating water on blue fuel can have two modifications:
- devices with an open combustion chamber;
- devices with a closed camera.
In most cases, the speaker is a compact device that is mounted on the wall. A fuel and water supply pipe is connected to it. The appliance needs a hood. The main components of the unit:
- ignition system;
- water heating unit;
- igniter;
- safety valve and sensor system;
- body;
- burner.
If the column has a closed fuel combustion chamber, air is forcibly pumped into it using a small fan. To control the column, an electronic unit is used that receives and processes data from built-in sensors. The task of the column is to heat running water. When the water in the tap is turned off, the device is in standby mode. When the valve is opened, the active heating of the heat exchanger begins. The heat exchanger itself is a thin copper coil. The water in it heats up and flows into the tap. As soon as the water flow stops, the automatic damper cuts off the gas access, and the column goes back to standby mode. This is the general principle of operation of columns with any combustion chamber device.
There are electronic ignition systems based on battery operation. In such devices, the igniter does not burn, and the burner ignites like in a stove, from a piezoelectric element. All water heaters with blue fuel are equipped with an emergency shutdown system. It is triggered if it receives signals from sensors when the pressure in the pipes decreases, damping and stopping the draft in the chimney. Most speakers have and temperature sensorslimiting the temperature of the heated water. Knowing the basic principles of operation and the layout of the column, you can draw preliminary conclusions why the gas column does not work.
How to properly turn on the gas column and adjust the temperature and pressure
The efficiency of its operation and its service life depend on the correct switching on and setting of the heater. It is important to correctly adjust the water supply in the gas column. In the documentation of the column, the capacity of the heat exchanger is usually written - from 6 to 12 liters. There is a toggle switch on the front panel.
If your home has problems with normal water pressure, experts recommend setting the toggle switch to maximum, and then adjusting the fuel toggle switch to achieve the desired temperature. How to light a gas column is described in the instructions for the device. The fuel supply is adjusted only after you have installed the batteries for ignition or connected the column to electricity, if the ignition is from the mains. Open the gas and hot water supply tap. The column should automatically turn on, and only then adjust the temperature.
Note! Do not expect boiling water to immediately flow from the tap. Heating occurs gradually. The more the tap is open, the lower the water temperature will be.
Keep in mind that the higher you set the heating temperature, the less the unit will work without breakdowns. That is, the wear of the heater is directly related to the temperature control mode.
Note! If your column is powered by bottled gas, have it set up by a certified technician. The fact is that for normal operation of the device, adjustment is required not with a toggle switch, but with an internal valve, for this you will have to remove the case and seals.
For rational fuel consumption, some modern units are equipped with a winter-summer mode adjustment. Check the technical documentation, the adjustment knob can be located on the front or on the bottom.
Related article:
Gas column "Neva". Where and how it is used, technical characteristics, model range, what to look for when buying, an overview of prices and user reviews - read our publication.
How easy it is to check the thrust in the gas column
In principle, the operation of the entire unit as a whole depends on the efficiency of the chimney duct. Good traction is needed for the combustion of fuel and the removal of combustion products outside the dwelling. If there is no thrust, the sensitive sensors of the equipment will give an alarm signal to the control system, and it will turn off the column. Professional repairmen have in their arsenal special devices for checking the intensity of traction. But what if there is no such device at hand, and the gas column does not ignite? You can simply check the presence or absence of movement in the chimney: bring a lighted match to the column window.
If not, keep in mind that in the event of a malfunction in the hood, the gas appliance must never be operated.
What tools are needed to repair a gas water heater with your own hands
Finding a problem in a gas water heater can take quite a long time and require patience and a certain set of tools from you:
- screwdriver with a regular and cross head;
- a set of keys (including gas);
- soldering iron;
- a file and sandpaper.
What to do with common gas water heater malfunctions
It is easy to repair simple units with an open combustion chamber with your own hands. If you have an imported expensive device stuffed with electronics installed, it is better to give up this idea. The consequences of inept repairs can be dire. Do not go into the unit, and if the warranty period has not expired.
There are several options for problems that are most common and can be fixed by the owner:
- leaks;
- difficulties with starting;
- shutdowns during operation.
You can try to cope on your own so in accordance with our recommendations.
Repair of the gas column heat exchanger in case of cracks or scale formation
If you find a crack in the heat exchanger, it can be "healed" with a soldering iron. If the damage is located in an accessible place, it is not necessary to remove the heat exchanger. Drain all the water. To do this, you need to turn off the supply to the apartment and open the hot water taps.
After drying the heat exchanger, sand the damaged area and degrease it with a solvent. The crack is then sealed with rosin and tin. Before starting the column, connect the water and check how well the repair was made.
If scale has formed in the heat exchanger tube, and this happens often in regions with "hard" water, you need to rinse the unit with any special descaling compound. To do this, the water is drained, and a hose is connected to the inlet of the heat exchanger through which the composition is poured. Hot water taps must be closed during the procedure! Leave the solution for two hours, during which time the hydrochloric acid will eat away all the scale, and you can drain it into a bucket. To speed up the process, you can ignite the pilot. Repeat the procedure twice to ensure good cleaning.
Important! When working with caustic products, take care of your hands and eyes, the liquid may splash in the face and flow past the heat exchanger. Use gloves and safety glasses.
What to do if the gas water heater does not light up
Gas heaters have a manual or automatic ignition system. The latest models from well-known manufacturers are equipped with a hydrogenerator, it is he who generates energy for ignition, so that with a weak water pressure or its absence, such columns may not ignite.
The column will not start working until you turn on the tap. The reason for the lack of reaction may be in the water pressure in the general network. Check, maybe the water was just turned off centrally? A similar reason is the lack of pressure in the gas pipe.
Malfunctions may be associated with a malfunction of the water unit, or "frogs" as it is popularly called. This is the valve that opens the fuel supply. If the geyser does not turn on when the water is turned on, then it unexpectedly works - look for damage in this unit. Elimination of the breakdown consists in replacing the membrane.
If the gas column igniter goes out after releasing the button
If the unit has a manual ignition, then the problems may be associated with the thermocouple. In this case, when the button is released, the igniter wick goes out. The reason is a breakdown of the solenoid valve.
Sometimes the wick goes out due to carbon deposits. This part can be easily removed and cleaned with a toothpick dipped in kerosene.
Why does the geyser spontaneously go out, and how to fix the problem
An unexpected termination of the heater's operation may be associated with the same water unit. If there is a large pressure of water, the valve works, and when the pressure decreases, it shuts off the fuel supply. The second reason for the spontaneous extinction of the column is the disappearance of thrust. Sensitive sensors react instantly and give a signal for emergency shutdown.
Often the solenoid valve fails - from time to time it is necessary to change this part of the unit. It's easy to check whether it works: you need to disconnect it from the case, without disturbing the wiring and remove it outside. If the unit continues to run, it is not the problem.
If all of the above reasons do not suit you, most likely it is the temperature sensor. You won't be able to check it without special equipment, so call a specialist.
Why does the gas water heater not heat the water
If there is a good water pressure, but the gas horse-tram does not heat well, the reasons are most likely in the formation of carbon deposits and soot on the outside of the heat exchanger. A layer of dirt traps heat and prevents the liquid from reaching the desired temperature. The same effect is created by scale. All of these parts need to be cleaned periodically.
The reason for the weak pressure of hot water from the gas column
Weak water pressure is an indicator of a clogged water supply system. In most cases, the cause is global and is a problem with the public network. But, perhaps, the filter mesh is clogged on the way to the "frog", check this assumption. A blockage can also form on the way from the dispenser to the tap. In this case, you need to organize a reverse flow of water and try to clear the pipes from the resulting blockage in this way.
What to do if the gas column radiator is leaking
The appearance of a puddle of water on the floor under the column is a signal of a radiator leak. Slack can be provided by union nuts and rubber seals. All of these parts are subject to replacement. In units with a safety valve, this part is the main cause of the leak. And, finally, the cause of the leak may be a crack in the heat exchanger, we wrote about its sealing above.
Replacing the gas column gaskets
The rubber seals in the column require periodic replacement. High temperatures and intensive use lead to damage to the integrity of the gaskets. Repair kits for a specific model can be purchased from authorized dealers and gas stores.
The most difficult process is replacing the frog membrane.It is she who is the most common reason why the geyser does not heat water well. How to replace this part - in a short video course.
Video: Neva gas column (Neva) 4510-4511 does not ignite: repair, membrane replacement
What to do if pops are heard when turning on the gas water heater
Pops when turning on the appliance indicate that an excessive amount of fuel has accumulated inside before ignition. Excess gas ignites with a small explosion, which you perceive as cotton. It is often a matter of dropping the spark plug. This happens for natural reasons, due to the constant temperature drop. The candle can simply be raised slightly by unscrewing the nut holding it. Poor-quality gas can also cause pops. Most often, problems arise with bottled fuel.
You smell gas during operation
The most unpleasant thing that can happen is the smell of gas in the house. Do not try to fix this problem yourself! Switch off all electrical appliances immediately, open windows and doors and call the emergency gas service immediately. Stay out of the room, leave it.
Features of repair of popular brands of gas water heaters
Popular brands of geysers, as a rule, suffer from the same problems that we wrote about above. But each manufacturer has its own weaknesses.
Features of repair of gas water heaters Bosch
The Bosch speakers are ignited using batteries, so check the battery charge first. Other problems with these units are common: contamination of the igniter, malfunction of the temperature controller and draft sensors. The main problem may be finding replacement parts as they are quite expensive and difficult to find.
The nuances of do-it-yourself repair of a Junkers gas column
Junkers speakers most often suffer from problems with the ignition system. They are treated by cleaning the pilot and replacing the thermocouple. These heaters need to be descaled at least once a year and the inlet water filters changed.
Repair of gas water heaters at home brand Oasis
The scheme of the Oasis geyser is not particularly different from others. Instructions for elementary repairs are in the technical data sheet of the product, and the alleged causes of the breakdown are also described in it. Factory defect in these devices is extremely rare, they are famous for their good quality. And the problems are most often associated with flaws in the installation and connection.
Features of repair of a gas column Vector
If the Vector gas column does not light up, replace the batteries. The set comes with very weak batteries, so don’t spare money for new ones. The emergency shutdown system in these devices has very rigid settings, so when there are pressure drops in the water and gas pipelines, do not expect good performance from the column. To rectify the situation, invite an experienced wizard to manually adjust these settings. A gas appliance, whether it be a stove, boiler or water heater, is a potentially dangerous object in the house. If you are not confident in your own knowledge and strength, do not take up repairs.
If you have your own options for repairing a geyser in your arsenal - write us about it in the comments!